276°
Posted 20 hours ago

POLYPIPE UFHPROGB PROGRAMMABLE Room Thermostat

£9.9£99Clearance
ZTS2023's avatar
Shared by
ZTS2023
Joined in 2023
82
63

About this deal

If the wiring was forgotten at the first-fix stage, or if it’s a retro-fit underfloor heating project where the floor construction cannot be lifted, there are wireless options we can offer. If a remote sensor is installed you can display all measured values by pressing the (OK) key (Scroll function).

With the cursor over the Comfort setting select and use the (-) or (+) keys to choose the Comfort temperature for the room. Validate with (OK). In the Auto mode this will be the temperature set for when the room is occupied only (On). If the cursor remains positioned over the room will permanently be set at the Comfort temperature. The valve to be adjusted will blink, and is adjusted with keys (-) and (+). Once the adjustment is made, accept it with the (OK) key. The thermostat will jump automatically to the next value. Progress of the adjustments Select any of U1 to U4 as this allows each thermostat to store up to 4 user defined programs in its memory.

Robert is the General Manager at Ambiente and has been working in the underfloor heating industry since 2012. If all periods for this day are finished press (OK) to accept or press (+) button to set the start time for the next period. A cookie set by YouTube to measure bandwidth that determines whether the user gets the new or old player interface. This is a unique anonymous session identifier cookie set by Microsoft Application Insights software to gather statistical usage and telemetry data for apps built on the Azure cloud platform. Here at Ambiente, our aim is to make UFH installation as painless and hassle-free as possible for all installers. With that in mind, we’ve put together this guide to answer some of the common questions we receive about wiring wet underfloor heating. If you have any further questions about UFH wiring that you think we should add, get in touch!

Press OK to make the P1/P9 adjustable. Use the (-) or (+) keys to choose P1 to P9, or U1 to U4 (User Defined Programs). Select and validate with (OK) to return to Auto. User Defined Programs U1 to U4This cookie, set by YouTube, registers a unique ID to store data on what videos from YouTube the user has seen.

To do this you will need to access the hidden user menu by setting the thermostat operation to AUTO and then holding down the (OK) button for 10 seconds. Then using the navigation button scroll to menu 07 and press (OK) then use the (+) to choose no and press (OK). Then using scroll to End and press (OK). Battery Access and User Controls You can set this temperature to run to the end of the day (midnight) by pressing (OK) or, use the (+) button to set the “off” time for this period To edit and existing user defined programme, select the existing programme in the Prog menu (U1 – U4) and press (OK) button.The wiring centre is where all the wiring for a UFH system meets. It is fed by a 230v fused-spur supply and coordinates the signals received from each of the heating thermostats. The zone valve on the primary heating circuit opens (only on the first thermostat calling for heat – it then remains open until the last thermostat reaches temperature) Another common problem with UFH wiring is ensuring that the correct wiring is run from each thermostat position. Most UFH thermostats require a 3-core + Earth, 1.5mm cable for 230v thermostats and a screened network cable for 12v thermostats. There are exceptions to this, however, for example, our DS-SB thermostats which require 4 core + earth cables.

The connection of the wet room sensor allows adjacent wet rooms to be controlled from a thermostat positioned outside the room. However the sensor can also be used to control floor surface temperatures where sensitive floor coverings are installed. When this function is operating, i.e. the thermostat is heating prior to the actual time setting, the will be displayed (flashing). If required this function can be de-activated in the user menu so as the heating will actually switch on at the chosen pre-set time. To access this menu set to the unit to the Off mode then hold down the (OK) key for 5 seconds. You will then access the hidden installer menu. Starting with menu 22, use the navigation keys to reach menu 23 REGU Air. Press (OK) to toggle between the options with the (-) and (+) keys and verify with (OK). If you choose FLR or FL.1, use the navigation keys to reach Menu 26 (FL:Lo) and set the floor low value. Then scroll to menu 27 (FL:Hi) and set the floor high value. To exit the installer menu scroll to menu 37 (End) and press (OK). Pre-set Programs My thermostat seems work correctly but the temperature in the room was never in accordance with the program Use the navigation keys to move from Auto to Prog as previous. Press (OK) to make P1/P9 adjustable.Use the navigation keys to move the frame cursor over the required mode and (OK) to confirm your choice. Once you know which wiring type is right for the system and the thermostat you’re installing, you can head to our resources section where you can choose between UH2, UH1, UH1-W, UH3, UH8-RF wiring centres as well as view a trades layout and single zone wiring diagram if needed.

Asda Great Deal

Free UK shipping. 15 day free returns.
Community Updates
*So you can easily identify outgoing links on our site, we've marked them with an "*" symbol. Links on our site are monetised, but this never affects which deals get posted. Find more info in our FAQs and About Us page.
New Comment